Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter

Specs at a Glance

Parameter Specification
Measurement Error (Standard) Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measurement Error (Option) Volume flow: ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring Range 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d)
Medium Temperature Range Hard rubber liner: 0 to +80 °C (+32 to +176 °F)
Polyurethane liner: –20 to +50 °C (–4 to +122 °F)
PTFE liner: –20 to +90 °C (–4 to +194 °F)
Process Pressure PN 40, Class 300, 20K
Wetted Materials Liner: Polyurethane / Hard rubber / PTFE
Electrodes: 1.4435 (316L), Alloy C22 (2.4602 / UNS N06022), Tantalum

Description

See all specifications

Field of application

The premium device for water and wastewater measurement Promag W 300 was designed for reliable use in hazardous areas and under harsh conditions. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.

 

 

Benefits

  • Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
  • Flexible engineering – sensor with fixed or lap-joint process connections
  • Long-term operation – robust and completely welded sensor
  • Improved plant availability – sensor compliant with industry-specific requirements
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to the measurement of industrial or municipal water and wastewater


Device properties

  • International drinking water approvals
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
  • Measuring principle

Electromagnetic

  • Product headline

Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter.
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
Dedicated to the measurement of industrial or municipal water and wastewater .

  • Sensor features

Flexible engineering – sensor with fixed or lap-joint process connections. Long-term operation – robust and completely welded sensor. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals.

  • Transmitter features

Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

DN 25 to 3000(1 to 120″)

  • Wetted materials

Liner: Polyurethane; Hard rubber, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

Volume flow, conductivity, mass flow

  • measurement error

Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

  • Measuring range

0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

  • process pressure

PN 40, Class 300, 20K

  • Medium temperature range

Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)

  • Ambient temperature range

Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 25 to 2400 (1 to 90″): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

  • Display/Operation

4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

  • Outputs

3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output

  • Inputs

Status input 4-20 mA input

  • Digital communication

HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

  • Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC

  • Product safety

CE, C-tick, EAC marking

  • Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Marine approvals and certificates

LR approval, DNV approval, ABS approval, BV approval

  • Pressure approvals and certificates

CRN, PED

  • Material certificates

3.1 material

  • Hygienic approvals and certificates