The flowmeter for highest medium temperatures with an ultra-compact transmitter

Specs at a Glance

Parameter Specification
Measurement Error Volume Flow (Standard): ±0.5% o.r. ± 1 mm/s (0.04 in/s)
Volume Flow (Option): ±0.2% o.r. ± 2 mm/s (0.08 in/s)
Measuring Range 4 dm³/min to 9,600 m³/h (1 to 44,000 gal/min)
Medium Temperature Range PFA Liner: –20 to +150 °C (–4 to +302 °F)
PFA High-Temperature Liner: –20 to +180 °C (–4 to +356 °F)
PTFE Liner: –40 to +130 °C (–40 to +266 °F)
Process Pressure PN 40, Class 300, 20K
Wetted Materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803)

Description

Specs at a glance

  • measurement error

Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s

  • Measuring range

4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

  • Medium temperature range

Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • process pressure

PN 40, Class 300, 20K

  • Wetted materials

Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)

Field of application

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.

 

 

Benefits

  • Versatile applications – wide variety of wetted materials
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Maintenance-free – no moving parts
  • Space-saving transmitter – full functionality on the smallest footprint
  • Time-saving local operation without additional software and hardware – integrated web server
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

Device properties

  • Nominal diameter: max. DN 600 (24″)
  • All common Ex approvals
  • Liner made of PTFE or PFA
  • Robust, ultra-compact transmitter housing
  • Local display available

 

 

 

 

  • Measuring principle

Electromagnetic

  • Product headline

The flowmeter for highest medium temperatures with an ultra-compact transmitter.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA.

  • Transmitter features

Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Local display available.

  • Nominal diameter range

DN 15 to 600 (½ to 24″)

  • Wetted materials

Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)

  • Measured variables

Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity

  • measurement error

Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s

  • Measuring range

4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

  • process pressure

PN 40, Class 300, 20K

  • Medium temperature range

Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • Ambient temperature range

Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

DN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish

  • Transmitter housing material

AlSi10Mg, coated

  • Degree of protection

IP66/67, type 4X enclosure

  • Display/Operation

4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible

  • Outputs

4‐20 mA HART (active)
Pulse/frequency/switch output (passive)

  • Inputs

None

  • Digital communication

HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET

  • Power supply

DC 20 to 30 V

  • Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO

  • Other approvals and certificates
  • Product safety

CE, C-Tick

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Marine approvals and certificates

LR approval, DNV approval, ABS approval, BV approval

  • Pressure approvals and certificates

PED, CRN

  • Material certificates

3.1 material

  • Hygienic approvals and certificates

Drinking water approval: ACS, NSF 61, WRAS