The flowmeter for highest medium temperatures with genuine loop-powered technology

Specs at a Glance

Parameter Specification
Measurement Error Volume Flow: ±0.5% o.r. ± 2 mm/s (0.08 in/s)
Measuring Range 4 dm³/min to 1,100 m³/h (1 to 4,850 gal/min)
Medium Temperature Range PFA Liner: –20 to +150 °C (–4 to +302 °F)
PTFE Liner: –40 to +130 °C (–40 to +266 °F)
Process Pressure PN 40, Class 300, 20K
Wetted Materials Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum

Description

See all specifications

Field of application

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With genuine loop-powered technology, Promag P 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.

 

 

Benefits

  • Versatile applications – wide variety of wetted materials
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Maintenance-free – no moving parts
  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

Device properties

  • Nominal diameter: max. DN 200 (8″)
  • All common Ex approvals
  • Liner made of PTFE or PFA
  • Loop-powered technology
  • Robust two-chamber housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
  • Measuring principle

Electromagnetic

  • Product headline

The flowmeter for highest medium temperatures with genuine loop-powered technology.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 200 (8″). All common Ex approvals. Liner made of PTFE or PFA.

  • Transmitter features

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

  • Nominal diameter range

DN 15 to 200 (½ to 8″)

  • Wetted materials

Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum

  • Measured variables

Volume flow, mass flow

  • measurement error

Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

4 dm3/min to 1100 m3/h (1 to 4850 gal/min)

  • process pressure

PN 40, Class 300, 20K

  • Medium temperature range

Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • Ambient temperature range

Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

AlSi10Mg, coated

  • Transmitter housing material

AlSi10Mg, coated

  • Degree of protection

IP66/67, type 4X enclosure

  • Display/Operation

4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

  • Outputs

4‐20 mA HART (passive)
Pulse/frequency/switch output (passive)

  • Inputs

None

  • Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Power supply

DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)

  • Hazardous area approvals

ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex, KC

  • Other approvals and certificates
  • Product safety

CE, C-Tick

  • Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

CRN, PED

  • Material certificates

3.1 material

  • Hygienic approvals and certificates

Drinking water approvals: ACS, NSF 61