描述
The Deltabar PMD50 is a high-performance metal membrane differential pressure transmitter engineered for precise measurement of flow, level, and differential pressure in both liquid and gas applications. Optimized for standard industrial environments, it combines robust sensor technology with an intuitive software wizard for fast, effortless commissioning.
Whether monitoring closed tanks or measuring volumetric flow rates across primary elements, the PMD50 delivers exceptional long-term stability and safety compliance (developed in accordance with IEC 61508 SIL standards) to keep your processes running smoothly.
Key Features & Benefits
- Plug-and-Play Commissioning: Built-in software wizards guide operators through quick setup, minimizing field configuration time.
- Enhanced Process Safety: Developed per IEC 61508 safety standards with flexible hardware/software write protection to prevent unauthorized adjustments.
- Pre-Assembled Efficiency: Available with pre-assembled, pressure- and leakage-tested manifolds to streamline onsite installation.
- Extended Thermal Limits: Operates safely in process temperatures ranging up to 400°C (752°F) when configured with high-quality diaphragm seals.
- Asset Management Ready: Equipped with an integrated RFID tag for fast digital identification and maintenance tracking in the field.
Technical Specifications
| Parameter | Specification Details |
| Measuring Principle | Differential Pressure |
| Reference Accuracy | Standard: up to 0.065% | Platinum: up to 0.055% |
| Measuring Cell Range | 100 mbar to 40 bar (1.45 psi to 580 psi) |
| Smallest Calibratable Span | 0.3 mbar (0.0043 psi) |
| Maximum Turn Down | 100:1 |
| Maximum Overpressure Limit | 375 bar (5,625 psi) |
| Long-Term Stability | 0.1% of URL/year | 0.2% of URL/5 years | 0.25% of URL/10 years |
| Process Temperature Range | -40°C to +110°C (-40°F to +230°F) (Up to 400°C / 752°F with diaphragm seal) |
| Ambient Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Vacuum Resistance | 25 mbar (0.0375 psi) |
| Supply Voltage | Ex d, Ex e, Non-Ex: 10.5…35V DC | Ex i: 10.5…30V DC |
| Communication Protocols | 4…20 mA HART |
| Process Connection | NPT1/4-18 |
| Membrane Materials | 316L Stainless Steel, AlloyC, Gold |
| Gasket Options | PTFE, FKM, EPDM, FFKM |
| Fill Fluid | Silicone oil, Inert oil |
| Housing Material | Aluminum, 316L Stainless Steel |
| Global Certificates | ATEX, FM, IECEx, JPN Ex, INMETRO, NEPSI, SIL |
| Design Compliance | EN10204-3.1, NACE MR0103, NACE MR0175 |
Product Comparison: Deltabar PMD50 vs. Standard DP Transmitters
Choosing the right instrumentation impacts your long-term operational costs. Here is how the Deltabar PMD50 compares against typical baseline differential pressure transmitters on the market:
| Feature / Capability | Deltabar PMD50 | Standard Baseline DP Transmitters |
| Best-in-Class Accuracy | Up to 0.055% (Platinum version) | Typically 0.1% to 0.2% |
| Long-Term Drift (10 Years) | Only 0.25% of URL | Often exceeds 0.5% to 1.0% of URL |
| Commissioning Speed | Fast via guided software wizards | Manual calibration and menu navigating |
| Asset Tracking | Built-in RFID Tag for digital scanning | Paper tags or stamped metal plates only |
| Overpressure Protection | Up to 375 bar (5625 psi) | Often limited to lower pressure thresholds |
| Safety Compliance | Developed per IEC 61508 (SIL) | Basic industrial compliance only |
Reliable Procurement with ZK Global Supply
At ZK Global Supply, we understand that precision instrumentation is critical to your plant’s efficiency and safety. We specialize in supplying authentic, high-grade industrial flow meters, pressure transmitters, and level sensors globally. Our technical team ensures your Deltabar PMD50 is configured exactly to your process parameters, backed by full certification compliance (NACE, EN10204-3.1) and dependable lead times.
Request a Quote Today: Contact our technical sales desk to get pricing, availability, or to discuss custom diaphragm seal configurations for your specific application.
❓ Frequently Asked Questions (FAQ)
Q1: What makes the Deltabar PMD50 more stable over long-term operations compared to baseline transmitters?
A: The Deltabar PMD50 features advanced metal membrane sensor technology that boasts exceptional resistance to long-term drift. It exhibits a minimal drift of just 0.25% of URL over a full 10-year operating cycle, drastically reducing the frequency and costs associated with routine field recalibration.
Q2: Can the PMD50 handle high-temperature and highly vacuumed process lines?
A: Yes. While the standard sensor cell operates up to +110°C (+230°F), configuring the Deltabar PMD50 with specialized high-quality diaphragm seals extends its safe thermal limits up to +400°C (+752°F). Additionally, it possesses a rugged vacuum resistance down to 25 mbar (0.0375 psi) abs.
Q3: How does the integrated RFID tag improve field asset management?
A: Unlike traditional paper labels or stamped metal tags that corrode in harsh environments, the PMD50 features a built-in digital RFID tag. Onsite technicians can instantly scan the device with a handheld reader to access factory calibration data, serial numbers, and maintenance logs, paving the way for digital plant tracking.