Flowmeter for basic hygienic applications with easy-to-use operation concept

Specs at a Glance

Parameter Specification
Measurement Error Volume Flow (Standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume Flow (Option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring Range 0.06 dm³/min to 600 m³/h (0.015 to 2,650 gal/min)
Medium Temperature Range –20 to +150 °C (–4 to +302 °F)
Process Pressure PN 40, Class 150, 20K
Wetted Materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: Stainless Steel 1.4404 (316L); PVDF; PVC Adhesive Sleeve
Seals: Aseptic Molded Seal (EPDM, FKM, Silicone)

Description

See all specifications

Field of application

Promag H is the preferred sensor for hygienic applications in the food and beverage and life sciences industries. With its straightforward hard- and software design, Promag H 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

 

 

Benefits

  • Easy integration into your plant infrastructure with IO-link
  • Flexible installation – numerous hygienic process connections and 0 x DN inlet run with constant accuracy independent of flow profile
  • Energy-saving flow measurement – no pressure loss due to cross section constriction
  • Maintenance-free – no moving parts
  • Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app
  • Simple, time-saving commissioning – guided parameterization in advance and in the field
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
  • For applications with sanitary requirements

Device properties

  • Liner made of PFA
  • Sensor housing made of stainless steel (3-A, EHEDG)
  • Wetted materials CIP-/SIP-cleanable
  • System integration with HART, Modbus RS485, IO-Link
  • Flexible operation with app and optional display
  • Measuring principle

Electromagnetic

  • Product headline

Flowmeter for basic hygienic applications with easy-to-use operation concept.
For applications with sanitary requirements.

  • Sensor features

Flexible installation concept – numerous hygienic process connections. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP-/SIP-cleanable.

  • Transmitter features

Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display.

  • Nominal diameter range

DN 2 to 150 (¹⁄₁₂ to 6″)

  • Wetted materials

Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)

  • Measured variables

Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity

  • measurement error

Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)

  • process pressure

PN 40, Class 150, 20K

  • Medium temperature range

–20 to +150 °C (–4 to +302 °F)

  • Ambient temperature range

–40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

1.4301 (304), corrosion resistant

  • Transmitter housing material

AlSi10Mg, coated

  • Degree of protection

Standard: IP66/67, type 4X enclosure

  • Display/Operation

2.4″ LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible

  • Outputs

4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA

  • Digital communication

HART, MODBUS RS485, IO-Link

  • Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

CSA, GP, KC

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

PED, CRN

  • Material certificates

3.1 material

  • Hygienic approvals and certificates

Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP