• Reliable flare gas flow measurement for refineries & chemical plants. FLOWSIC100 Flare-XT supports 0.03 to 120 m/s range with mass flow calculation and predictive maintenance.

描述

Product Overview

Mastering Extreme Flows: The Ultimate Flare Gas Solution.

In the demanding environments of petroleum refineries and natural gas processing, precision is not just a requirement—it’s a safety mandate. The FLOWSIC100 Flare-XT is engineered to provide stable measurements across an incredible dynamic range (up to 120 m/s).

At https://www.google.com/url?sa=E&source=gmail&q=hanyuzl.com, we provide this intelligent system to help plants detect leaks, optimize steam injection, and monitor gas losses in real-time. With its direct mass flow calculation, you no longer need complex external gas analyzers, simplifying your infrastructure while ensuring compliance with ATEX and PED standards.

Technical Specifications at a Glance

Feature Technical Data
Measuring Range 0.03 m/s to 120 m/s (0.1 ft/s to 394 ft/s)
Measured Variables Mass flow, Volumetric flow (s.c. & a.c.), Molecular weight, Sound velocity
Compliance ATEX (2014/34/EU), EMC, RoHS, PED
Software Interface FLOWgate™ for intuitive diagnostics and commissioning
Application Areas Refineries, Chemical plants, LNG Boil-off, APG processing

Why Upgrade to Flare-XT? (Comparative Advantage)

Capability FLOWSIC100 Flare-XT Conventional Flare Meters
Velocity Range Ultra-wide (up to 120 m/s) Often limited to <80 m/s
Mass Flow Direct calculation (No analyzer needed) Requires additional gas analysis
Maintenance Predictive (Self-monitoring) Reactive (Fix after failure)
Low Flow Sensitivity Measures down to 0.03 m/s Struggles with low-flow leak detection

Application Case: LNG Boil-off Gas Monitoring

The Challenge: A natural gas processing facility struggled with inconsistent flow readings during high-velocity flare events, leading to inaccurate environmental reporting.

The Solution: By integrating the FLOWSIC100 Flare-XT via https://www.google.com/url?sa=E&source=gmail&q=hanyuzl.com, the facility achieved stable readings even during peak discharge. The i-diagnostics™ and FLOWgate™ software allowed the team to perform “health checks” remotely, reducing the need for dangerous flare stack climbs by 60%.

Frequently Asked Questions

  • Q: What is the measuring range of the FLOWSIC100 Flare-XT?
    • A: The FLOWSIC100 Flare-XT offers an ultra-wide measuring range from 0.03 m/s to 120 m/s. This allows it to detect minor leaks as well as handle high-velocity flow during emergency flare events.
  • Q: Does it require an additional gas analyzer for mass flow calculation?
    • A: No. One of its key advantages is the direct mass flow calculation feature, which operates based on molecular weight and sound velocity without needing external analyzers.
  • Q: Is the Flare-XT suitable for hazardous environments?
    • A: Absolutely. It is fully compliant with ATEX (2014/34/EU) and PED standards, ensuring safe and reliable operation in refineries and chemical processing zones.