The cost-effective limit switch for reliable and repeatable flow monitoring

Specs at a Glance

Parameter Specification
Measurement Error 2%
Measuring Range 0 to 56,550 m³/h
Medium Temperature Range -20 to +120°C (-4 to +248°F)
Process Pressure 0 to 16 bar abs
Wetted Materials 1.4435 / 316L

Description

See all specifications

Field of application

The cost-effective, compact limit switch Magphant is an ideal flowmeter for water applications in Utilities. Its reliable measurement with high repeatability allows for univesal and easy use and supports safe process- and plant operation.

 

 

Benefits

  • High plant availability – reliable flow information
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Maintenance-free – no moving parts
  • Process safety – device self-monitoring and reliable monitoring even with empty piping
  • Product safety – integrated testing to check correct functioning of the electronics
  • Easy operation – potentiometer setting of full-scale value
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Universally usable for all water applications in Utilities.

Device properties

  • Compact, space-saving design
  • Nominal diameter: DN 15 to 2000 (1/2 to 80″)
  • Applicable for steel or plastic pipes
  • Switch point setting via rotary switch
  • Current output and relay output
  • ATEX, FM, CSA
  • Measuring principle

Electromagnetic

  • Product headline

.

  • Sensor features

High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80″).

  • Transmitter features

Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output.

  • Nominal diameter range

DN15 to DN2000
1/2″ to 80″

  • Wetted materials

1.4435/316L

  • Measured variables

Volume flow

  • measurement error

2%

  • Measuring range

0 to 56’550 m3/h

  • process pressure

0 to 16 bar abs

  • Medium temperature range

-20 to +120°C
(-4 to +248°F)

  • Ambient temperature range

-20…60 °C (-4 to 140°F)

  • Sensor housing material

Die-cast aluminium, epoxy powder coated

  • Degree of protection

IP 66 / NEMA 4X / Type 4X

  • Display/Operation

Test function

  • Outputs

4 to 20 mA
Relay

  • Inputs

None

  • Power supply

24 V DC (20…30 V DC)

  • Hazardous area approvals

FM
CSA

  • Product safety

CE, EAC