Flowmeter for basic water and wastewater applications with easy-to-use operation concept

Specs at a Glance

Parameter Specification
Measurement Error Volume Flow (Standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring Range 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d)
Medium Temperature Range Hard Rubber Liner: 0 to +80 °C (+32 to +176 °F)
Polyurethane Liner: –20 to +50 °C (–4 to +122 °F)
PTFE Liner: –20 to +90 °C (–4 to +194 °F)
Process Pressure PN 40, Class 300, 20K
Wetted Materials Liner Materials: Hard Rubber, Polyurethane, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

Description

See all specifications

Field of application

Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.

 

 

Benefits

  • Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss
  • Flexible engineering – sensor with fixed or lap-joint process connections
  • Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
  • Improved plant availability – sensor compliant with industry-specific requirements
  • Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
  • Simple, time-saving commissioning – guided parameterization in advance and in the field
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
  • Suitable for elementary measurement tasks such as raw water intake.

Device properties

  • International drinking water approvals
  • Degree of protection IP68 (Type 6P enclosure)
  • System integration with HART, Modbus RS485
  • Flexible operation with app and optional display
  • Measuring principle

Electromagnetic

  • Product headline

Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
Suitable for elementary measurement tasks such as raw water intake.

  • Sensor features

Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform.

  • Transmitter features

Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.

  • Nominal diameter range

DN 25 to 3000(1 to 120″)

  • Wetted materials

Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

  • Measured variables

Volume flow, conductivity, mass flow

  • measurement error

Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

  • Measuring range

0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

  • process pressure

PN 40, Class 300, 20K

  • Medium temperature range

Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194°F)

  • Ambient temperature range

-40 to 60°C (-40 to 140°F)

  • Sensor housing material

DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 350 to 2000 (14 to 78″): Carbon steel with protective varnish

  • Transmitter housing material

Polycarbonat; AlSi10Mg, coated

  • Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3

  • Display/Operation

LCD display with touch & auto rotate

  • Outputs

4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA

  • Digital communication

HART, MODBUS RS485, IO-Link

  • Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

CSA, GP, KC

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

CRN, PED

  • Material certificates

3.1 material

  • Hygienic approvals and certificates

Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920