Flowmeter for basic process applications with easy-to-use operation concept

Specs at a Glance

Parameter Specification
Measurement Error Volume Flow (Standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume Flow (Option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring Range 4 dm³/min to 9,600 m³/h (1 gal/min to 44,000 gal/min)
Medium Temperature Range PFA Liner: –20 to +150 °C (–4 to +302 °F)
PTFE Liner: –40 to +130 °C (–40 to +266 °F)
Process Pressure PN 40, Class 300, 20K
Wetted Materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

Description

See all specifications

Field of application

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With its straightforward hard- and software design, Promag P 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables safe processes.

 

 

Benefits

  • Diverse applications – wide variety of wetted materials
  • Accurate measurement independent of disturbed flow profiles after obstacles in the pipe thanks to 0 x DN full-bore option
  • Energy-saving flow measurement – no pressure loss due to cross section constriction
  • Maintenance-free – no moving parts
  • Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
  • Simple, time-saving commissioning – guided parameterization in advance and in the field
  • Integrated verification – Heartbeat Technology
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
  • Dedicated to chemical and process applications with corrosive liquids.

Device properties

  • Nominal diameter: max. DN 600 (24″)
  • All common Ex approvals
  • Liner made of PTFE or PFA
  • System integration with HART, Modbus RS485
  • Flexible operation with app and optional display

 

 

 

  • Measuring principle

Electromagnetic

  • Product headline

Flowmeter for basic process applications with easy-to-use operation concept.
Dedicated to chemical and process applications with corrosive liquids.

  • Sensor features

Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA.

  • Transmitter features

Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.

  • Nominal diameter range

DN 15 to 600 (½ to 24″)

  • Wetted materials

Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

  • Measured variables

Volume flow, conductivity, mass flow

  • measurement error

Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

  • process pressure

PN 40, Class 300, 20K

  • Medium temperature range

Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • Ambient temperature range

Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

DN 15 to 300 (½ to 12″”): AlSi10Mg, coated
DN 350 to 600 (14 to 24″”): Carbon steel with protective varnish

  • Transmitter housing material

AlSi10Mg, coated

  • Degree of protection

Standard: IP66/67, Type 4X enclosure

  • Display/Operation

2.4″ LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible

  • Outputs

4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA

  • Digital communication

HART, MODBUS RS485, IO-Link

  • Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, IND Ex, KC, JPN, UK Ex

  • Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

PED, CRN

  • Material certificates

3.1 material

  • Hygienic approvals and certificates

Driking water approvals: ACS; NSF61, WRAS